Technical Summary
| Model | 1FK7085-4CF71-1UH1 |
|---|---|
| Product type | SIMOTICS S Synchronous motor |
| Rated speed (100 K) | 3,000 rpm |
| Static torque (100 K) | 22.00 Nm |
| Rated current | 7.0 A |
| Number of poles | 8 |
| Cooling | Natural cooling |
| Degree of protection | IP65 |
| Encoder system | Resolver R15DQ: resolver 15 bits (resolution 32768, internal multi- pole) |
| Holding brake | Permanent-magnet brake |
| Power supply voltage | DC 24 V ± 10 % |
| Design acc. to Code I | IM B5 (IM V1, IM V3) |
Key Features
PN=2kW, UDC=600V, M0=22Nm (100K), and NN=3000rpm.
Resolver multi-pole with DRIVE-CLiQ interface.
Naturally cooled with degree of protection IP65.
Plain shaft, tolerance N, with holding brake.
IM B5 (IM V1, IM V3) with rotatable power connectors and signal connectors.
Applications
Motor for use in SINAMICS S120 systems.
Frequently Asked Questions
What is Siemens 1FK7085-4CF71-1UH1?
It is a SIMOTICS S synchronous motor in the 1FK7 servomotors for SINAMICS S120 category.
What are the rated speed and torque of 1FK7085-4CF71-1UH1?
Rated speed (100 K) is 3,000 rpm and static torque (100 K) is 22.00 Nm.
Which feedback system does 1FK7085-4CF71-1UH1 use?
It uses Resolver R15DQ: resolver 15 bits (resolution 32768, internal multi- pole) with DRIVE-CLiQ interface.
What mounting and protection details are listed for 1FK7085-4CF71-1UH1?
Design acc. to Code I is IM B5 (IM V1, IM V3), and the degree of protection is IP65.
Does 1FK7085-4CF71-1UH1 include a holding brake?
Yes. It is specified with a permanent-magnet holding brake with holding torque 22.0 Nm and power supply voltage DC 24 V ± 10 %.