Technical Summary
| Product type | SIMOTICS S Synchronous motor |
|---|---|
| Model variant | 1FK7-HD |
| Rated power | PN=2.4kW |
| DC link voltage | UDC=600V |
| Static torque (100 K) | M0=12Nm |
| Rated speed (100 K) | 4,500 rpm |
| Cooling | Natural cooling |
| Degree of protection | IP64 |
| Encoder system | Encoder AM24DQI: absolute encoder 24 bits (resolution 16777216, encoder-internal 2048 S/R) + 12 bits multi-turn (traversing range 4096 revolutions) |
| Holding brake | with holding brake |
| Shaft end | Plain shaft |
| Design acc. to Code I | IM B5 (IM V1, IM V3) |
Key Features
1FK7-HD motor type for SINAMICS S120.
PN=2.4kW, UDC=600V, and M0=12Nm (100K).
NN=4500rpm.
Absolute encoder 24 BIT + 12 BIT MULTITURN with DRIVE-CLiQ interface (ENCODER AM24DQI).
Naturally cooled, FRAME SIZE IMB 5 (IM V1, IM V3), plain shaft, and with holding brake.
Degree of protection IP64.
Applications
Servomotor use in SINAMICS S120 drive systems.
Frequently Asked Questions
What is the exact product model of Siemens 1FK7064-4CH71-1CH0?
It is a SIMOTICS S synchronous motor, 1FK7-HD.
What are the main electrical ratings of 1FK7064-4CH71-1CH0?
PN=2.4kW, UDC=600V, and rated current 7.0 A.
What encoder does 1FK7064-4CH71-1CH0 use?
It uses ENCODER AM24DQI with an absolute encoder 24 BIT + 12 BIT MULTITURN and DRIVE-CLiQ interface.
What mechanical configuration does 1FK7064-4CH71-1CH0 have?
It is naturally cooled, has FRAME SIZE IMB 5 (IM V1, IM V3), a plain shaft, and a holding brake.