Technical Summary
| Product type | SIMOTICS S Synchronous motor 1FK7-HD |
|---|---|
| Rated power | PN=2.4kW |
| Rated voltage | UDC=600V |
| Rated speed (100 K) | 4,500 rpm |
| Static torque (100 K) | 12.00 Nm |
| Maximum torque | 32.0 Nm |
| Encoder system | Encoder IC22DQ: incremental encoder 22 bits (resolution 4194304, encoder-internal 2048 S/R) + commutation position 11 bits |
| Cooling | Natural cooling |
| Degree of protection | IP65 and DE flange IP67 |
| Design acc. to Code I | IM B5 (IM V1, IM V3) |
| Shaft end | Plain shaft |
| Holding brake version | Permanent-magnet brake |
Key Features
SIMOTICS S Synchronous motor 1FK7-HD for the 1FK7 servomotors for SINAMICS S120 category.
PN=2.4kW, UDC=600V, M0=12Nm (100K), and NN=4500rpm.
Incremental encoder 22 BIT with DRIVE-CLIQ interface (ENCODER IC22DQ).
Naturally cooled, design acc. to Code I IM B5 (IM V1, IM V3).
Degree of protection IP65 and DE flange IP67, with plain shaft, tolerance N.
With holding brake and permanent-magnet brake version.
Frequently Asked Questions
What is Siemens 1FK7064-4CH71-1DH2?
It is a SIMOTICS S synchronous motor, 1FK7-HD.
What are the main ratings of 1FK7064-4CH71-1DH2?
PN=2.4kW, UDC=600V, M0=12Nm (100K), and NN=4500rpm.
Which encoder is used on 1FK7064-4CH71-1DH2?
It uses an incremental encoder 22 BIT with DRIVE-CLIQ interface (ENCODER IC22DQ).
What protection and mounting data does 1FK7064-4CH71-1DH2 have?
It has IP65 protection and DE flange IP67, with design acc. to Code I IM B5 (IM V1, IM V3).