Technical Summary
| Product type | SIMOTICS S Synchronous motor |
|---|---|
| PN | 4.3kW |
| UDC | 600V |
| M0 | 27Nm (100K) |
| NN | 2000rpm |
| Cooling | Naturally cooled |
| Mounting | FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1 |
| Feedback | Absolute encoder 32 S/R singleturn, 4096 rotation multiturn, with ENDAT-INTERFACE (ENCODER AM32S/R) |
| Shaft | plain shaft, tolerance N |
| Holding brake | without holding brake |
| Protection | IP65 DE flange IP67 |
| Power connector | rotatable |
Key Features
PN=4.3kW
UDC=600V, M0=27Nm (100K), NN=2000rpm
Naturally cooled, FRAME SIZE IMB 5 (IM V1, IM V3) FLANGE 1
Absolute encoder 32 S/R singleturn, 4096 rotation multiturn, with ENDAT-INTERFACE (ENCODER AM32S/R)
Plain shaft, tolerance N; without holding brake; degree of protection IP65 DE flange IP67
Applications
Motor use in SINAMICS S120 motion control systems.
Frequently Asked Questions
What is Siemens 1FK7101-2AC71-1GG2?
It is a SIMOTICS S synchronous motor.
What are the main power and speed values for 1FK7101-2AC71-1GG2?
PN=4.3kW, UDC=600V, M0=27Nm (100K), and NN=2000rpm.
What encoder is fitted on 1FK7101-2AC71-1GG2?
It uses an absolute encoder 32 S/R singleturn, 4096 rotation multiturn, with ENDAT-INTERFACE (ENCODER AM32S/R).
What protection and mechanical details are listed for 1FK7101-2AC71-1GG2?
It has a plain shaft, tolerance N, without holding brake, and degree of protection IP65 DE flange IP67.