Technical Summary
| Product type | SIMOTICS M compact asynchronous motor |
|---|---|
| Speed rating 1 | 400 r/min |
| Power at 400 r/min | 30.4 kW |
| Torque at 400 r/min | 726 Nm |
| Current at 400 r/min | 86 A |
| Voltage at 400 r/min | 268 V |
| Speed rating 2 | 500 r/min |
| Power at 500 r/min | 38 kW |
| Torque at 500 r/min | 726 Nm |
| Current at 500 r/min | 85 A |
| Voltage at 500 r/min | 335 V |
| Speed rating 3 | 600 r/min |
| Power at 600 r/min | 45 kW |
| Torque at 600 r/min | 716 Nm |
| Current at 600 r/min | 83 A |
| Voltage at 600 r/min | 405 V |
| Cooling | forced ventilation direction of air flow NDE–>DE |
| Degree of protection | IP55 |
| Encoder | Incremental encoder HTL 1024 S/R (encoder HTL1024S/R) |
| Temperature sensor | KTY 84-130 |
| Design | IM B3 (IMB6, IMB7, IMB8, IMV6) |
| Shaft | shaft with fitted key |
| Balancing | HALF-KEY BALANCING |
| Bearing | BEARING: STANDARD |
| Vibration severity | VIBRATION SEVERITY GRADE A |
| Terminal box | TERMINAL BOX (ABOVE) |
| Cable entry | CABLE ENTRY ON THE RIGHT |
| Signal connection | SIGNAL CONNECTION D-END |
Key Features
Compact asynchronous motor in the SIMOTICS M range.
400 r/min, 500 r/min, and 600 r/min ratings are listed for this motor.
Forced ventilation with air flow NDE–>DE.
Degree of protection: IP55.
Incremental encoder HTL 1024 S/R (encoder HTL1024S/R).
With temperature sensor KTY 84-130.
Applications
Suitable as a motor in the 1PH8 for SINAMICS S120 for production machines category.
Supports drive operation at 400 r/min, 500 r/min, and 600 r/min.
Frequently Asked Questions
What is Siemens 1PH8224-1HB10-2AA1?
It is a SIMOTICS M compact asynchronous motor.
What are the speed ratings for 1PH8224-1HB10-2AA1?
The listed speed ratings are 400 r/min, 500 r/min, and 600 r/min.
What encoder is included with 1PH8224-1HB10-2AA1?
It uses an incremental encoder HTL 1024 S/R (encoder HTL1024S/R).
What degree of protection does 1PH8224-1HB10-2AA1 have?
The degree of protection is IP55.
What installation and connection details are listed for 1PH8224-1HB10-2AA1?
It is listed with IM B3 (IMB6, IMB7, IMB8, IMV6), a terminal box above, cable entry on the right, and signal connection D-END.